OUR PRODUCT

NYA ( Cu/PVC )

(Copper Conductor, PVC Insulated )

Standard Specification

SNI 04-6629.3

IEC 60227-3 Other specifications are available upon request

Rated Voltage450/750 V
Number of Core1 Core
Cross-sectional Area1.5MM – 400MM
ApplicationFor building wire installed in conduit in dry location and inter wiring in switch board and control panel.
Conductor Shape
  • 1.5 – 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
  • 16 – 400 sqmm supplied in non-compacted circular stranded (rm)

NYM ( Cu/PVC/PVC )

(Copper Conductor, PVC Insulated, PVC Sheathed )

Standard SpecificationSNI 04-6629.4  Other specifications are available upon request
Rated Voltage300/500 V
Number of Core2 – 5 core
Cross-sectional Area1.5 – 35 mm²
ApplicationFor building wire installed in conduit in dry location and inter wiring in switch board and control Panel.
Conductor Shape
  • 1.5 – 2.5 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape

  • 4 – 35 sqmm supplied in non compacted circular stranded (rm) conductor shape

NYY ( CU / PVC / PVC )

(Copper Conductor, PVC Insulated, PVC Sheathed)

Standard Specification

SNI IEC 60502-1 : 2009

IEC 60502-1. Other specifications are available upon request

Rated Voltage0.6kV/1.0kV
Number of Core

1 – 5 Core

Single Core (1 Core 1.5 – 600 mm²)

Cross-sectional Area1.5mm – 600mm
ApplicationPower cable : indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
Conductor Shape
  • 1.5 – 10 sq.mm supplied in solid (re) or non compacted circular stranded (rm).
  • 16 sq.mm supplied in non compacted circular stranded (rm) conductor shape.
  • 25 – 800 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape.

N2XY ( CU / XLPE / PVC )

(Copper Conductor, XLPE Insulated, PVC Sheathed)

Standard Specification

SNI IEC 60502-1 : 2009

IEC 60502-1. Other specifications are available upon request

Rated Voltage0.6kV – 1.0kV
Number of Core

1 – 5 Core

Cross-sectional Area1.5MM – 500MM
ApplicationPower cable : indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear as well as for urban supply networks, if mechanical damage is unlikely.
Conductor Shape
  • 1.5 – 10 sqmm supplied in coil @ 100 m

  • 16 – 400 sqmm supplied in a wooden drum @ 1000 m

  • 500 – 800 sqmm supplied in a wooden drum on available length

  • 1.5 – 120 sqmm supplied in a wooden drum @ 1000 m

  • 150 – 300 sqmm will be supplied in a wooden drum on available length

  • Length Tolerance per drum ± 2%

NYFGbY ( Cu / PVC / SFA / PVC ), and NYRGbY ( Cu / PVC / SWA / PVC )

(Copper Conductor, PVC Insulated, Galvanized Steel Flat Wire Armor, PVC Sheathed)

Standard Specification

SNI IEC 60502-1 : 2009

IEC 60502-1

Other specifications are available upon request

Rated Voltage0.6kV/1.0kV
Number of Core

2 – 5 Core

Cross-sectional Area1.5MM – 300MM
ApplicationFor installation in the ground, indoors, cable trunking and outdoors if increased mechanical protection is required or where high-pulling stresses may occur during installation or operation
Conductor Shape
  • 1.5 – 10 sq.mm supplied in solid (re) or non-compacted circular stranded (rm)

  • 16 sq.mm supplied in non-compacted circular stranded (rm) conductor shape

  • 25 – 800 sqmm supplied in non-compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape

N2XSY ( Cu / XLPE / CTS / PVC )

(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed)

Standard Specification

SNI IEC 60502-2 : 2009

IEC 60502-2

Other specifications are available upon request

Rated Voltage

3.6/6 kV up to 18/30 kV

Number of Core

1 Core

Cross-sectional Area

25 – 800 mm²

Application

For power stations and switchgear as well as stations because of small bending radius in confined spaces indoors. As underground because of light weight where installation conditions are difficult.

Conductor Shape

25 – 800 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape

N2XSEBY(Cu/XLPE/CTS/PVC/STA/PVC)

(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel TapeArmor, PVC  Sheathed)

Standard Specification

SNIIEC60502-2:2009 

IEC60502-2 (Other specifications are available upon request)

Rated Voltage3.6/6kV up to18/30kV
Number of Core

3 Core

Cross-sectional Area25–300mm²
ApplicationFor installation indoor, in ground direct buried for power station and switchgear,if there is arisk that low mechanical damage may occur.
Conductor Shape25-300sqmm supplied in ompacted circular stranded (cm ) conductor shape

N2XY – FRC | FIRE RESISTANT CABLE

(Copper Conductor, Mica tape, XLPE Insulated, PVC Sheathed)

Fire Resistant Cable are specifically designed to facilitate the quick and orderly evacuation of the buildings occupants in the event of an emergency. propose designed to maintain circuit integrity to a host of critical safety system, including fire alarms, loud Speaker, emergency ligths, CCTV systems Smoke detector and emergency power supplies. In management systems, emergency power supply, lift,elevator and emergency lightingsIn chemical industry, textile industry, oil refinery, machine industry, power station.

Standard Specification

SNI IEC 60502-1 : 2009

IEC 60502-1 : 2004 and IEC 60331

Rated Voltage
  • 300V/500V for instruments and controls
  • 0.6kV – 1.0kV for Power cables
Number of Core

1-5 cores (above 5 cores indent by production)

Cross-sectional Area1.5MM – 300MM.
Other size by request
ApplicationFor installation indoor, in ground direct buried for power station and switchgear,if there is arisk that low mechanical damage may occur.
Conductor Shape
  • 1.5-10 sqmm supplied in solid (re) or non-compacted circular stranded (rm) conductor shape.
  • 16 sqmm supplied in non-compacted circular stranded (rm) conductor shape.
  • 25 -300 sqmm supplied in compacted circular stranded (cm) conductor shape.